ELUTRA LABS
Independent Chemical Analysis
Sydney & Melbourne, Australia

Certificate of Analysis

ELU-K3WMTX9AV2
Issued: 27 March 2025
Sample Information
Report ID
ELU-K3WMTX9AV2
Sample Name
Tirzepatide 10mg
Category
GLP-1
Claimed Dose
10mg
Date Received
24 March 2025
Date Reported
27 March 2025
Laboratory
Elutra Labs — Sydney
Analyst
AC-02
Test Results
FAIL
Overall Result
FAIL
Identity Confirmed
Tirzepatide
Claimed Dose
10mg
Measured Dose
3.1mg (31%)
Purity (HPLC)
94.20%
Contaminants
None detected
Verification

Verify this report

This report is permanently stored in the Elutra Labs public database and cannot be altered after publication.

elutralabs.com/verify/ELU-K3WMTX9AV2
Disclaimer: Elutra Labs provides independent chemical analysis for harm reduction and research purposes. We do not sell, supply, or endorse any substances tested. Results are for informational purposes only. Users are solely responsible for compliance with applicable laws in their jurisdiction. This certificate was generated on 27 March 2025 and reflects the condition of the sample as received. Analytical error: ±5% for quantification, ±0.5% for purity determination.
Elutra Labs Pty Ltd
Sydney & Melbourne, Australia
info@elutralabs.com
Report ELU-K3WMTX9AV2
Page 1 of 1